Applies To: 1999–03 3.2 TL – ALL, 2001–03 3.2 CL – ALL
Blower Motor Does Not Work
SYMPTOM
The blower motor does not work at all.
PROBABLE CAUSE
Poor connection at the blower motor caused by tension on the wiring harness.
CORRECTIVE ACTION
Install a blower motor subharness.
REPAIR PROCEDURE
1. Remove the glove box and cover:
• 1999–03 3.2 TL: See page 20-66 of the 1999–03 3.2 TL Service Manual.
• 2001–03 3.2 CL: See page 20-64 of the 2001–03 3.2 CL Service Manual.
• Online, enter keyword GLOVE, and select Glove Box Removal/Installation from the list.
2. Disconnect the brown 7P connector (C202) from the main harness. Remove the YEL/BLK wire terminal from cavity 3 of connector C202. Cut off the terminal, and tape the remaining end of the wire to the harness.
NOTE: If necessary, refer to the terminal replacement section of the appropriate ETM for how to properly remove a terminal from a connector. ... Download File PDF